Search results for " silicone"
showing 10 items of 10 documents
Polylactic is a Sustainable, Low Absorption, Low Autofluorescence Alternative to Other Plastics for Microfluidic and Organ-on-Chip Applications
2020
Organ-on-chip (OOC) devices are miniaturized devices replacing animal models in drug discovery and toxicology studies. The majority of OOC devices are made from polydimethylsiloxane (PDMS), an elastomer widely used in microfluidic prototyping, but posing a number of challenges to experimentalists, including leaching of uncured oligomers and uncontrolled absorption of small compounds. Here we assess the suitability of polylactic acid (PLA) as a replacement material to PDMS for microfluidic cell culture and OOC applications. We changed the wettability of PLA substrates and demonstrated the functionalization method to be stable over a time period of at least 9 months. We successfully cultured …
Microfabrication of hybrid fluid membrane for microengines
2015
International audience; This paper describes the microfabrication and dynamic characterization of thick membranes providing a technological solution for microengines. The studied membranes are called hybrid fluid-membrane (HFM) and consist of two thin membranes that encapsulate an incompressible fluid. This work details the microelectromechanical system (MEMS) scalable fabrication and characterization of HFMs. The membranes are composite structures based on Silicon spiral springs embedded in a polymer (RTV silicone). The anodic bonding of multiple stacks of Si/glass structures, the fluid filling and the sealing have been demonstrated. Various HFMs were successfully fabricated and their dyna…
TREATMENT OF PERSISTENTLY OPEN MACULAR HOLES WITH HEAVY SILICONE OIL (DENSIRON 68) VERSUS C2F6. A PROSPECTIVE RANDOMIZED STUDY
2016
Abstract PURPOSE: To compare the efficacy of a mixture of silicone oil and perfluorohexyloctane (Densiron 68) with C2F6 gas endotamponade in the retreatment of persistently open full-thickness macular holes. METHODS: In this prospective randomized study, 21 consecutive patients who were unsuccessfully operated on for large idiopathic full-thickness macular hole were randomly assigned to undergo a second vitrectomy with 20% perfluoroethane gas (C2F6, Group A) or with Densiron 68 tamponade (Group B). PRIMARY OUTCOMES: Endpoint (12 months) full-thickness macular hole closure rate by spectral domain optical coherence tomography and logMAR corrected distance visual acuity. SECONDARY OUTCOMES: po…
Additive Manufacturing of Multi‐Scale Porous Soft Tissue Implants That Encourage Vascularization and Tissue Ingrowth
2021
Medical devices, such as silicone-based prostheses designed for soft tissue implantation, often induce a suboptimal foreign-body response which results in a hardened avascular fibrotic capsule around the device, often leading to patient discomfort or implant failure. Here, it is proposed that additive manufacturing techniques can be used to deposit durable coatings with multiscale porosity on soft tissue implant surfaces to promote optimal tissue integration. Specifically, the “liquid rope coil effect”, is exploited via direct ink writing, to create a controlled macro open-pore architecture, including over highly curved surfaces, while adapting atomizing spray deposition of a silicone ink t…
Micro‐tomographic characterization of composite recycled glass‐silicone foams for applications in civil engineering
2019
Noninvasive X‐ray micro‐computed tomography was applied for a complete quantitative and qualitative analysis of the cellular structure of composite foams constituted by a silicone matrix and a glass production waste filler. Composite foams with different glass filler weight content in the range 0–80% were synthesized and characterized. The tomographic analysis was employed in order to assess the structural heterogeneities, void fraction values, and bubble size distribution for all composite foams. The 3D micro‐CT images analysis, performed at different cross‐sections, highlighted heterogeneous cell growth or more elongated cells in the case of low and high filler content foams, respectively…
Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.
2009
The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recover…
The Use of Silicones as Extractants of Biologically Active Substances from Vegetable Raw Materials
2021
Based on theoretical studies, the authors of this paper propose the use of cosmetic organosilicon polymers (commonly called silicones) for the extraction of a complex of biologically active substances contained in vegetable raw materials. It is important to note that the biological molecules do not interact with the organosilicones and, therefore, their properties are not altered after the extraction. In this work, we investigate the efficiency of several polyorganosiloxanes as extractants of vegetable raw materials (Calendula Officialis L. and Artemisia Absinthium L.) useful for the preparation of cosmetic emulsions. Specifically, the extraction studies were conducted by using polyorganosi…
A diagnostic trap for the dermatopathologist: granulomatous reactions from cutaneous microimplants for cosmetic purposes.
2007
We present a case of late granulomatous reactions from silicone that first appeared in a site different from that of the injection causing an incorrect diagnosis of liposarcoma in the beginning. The histological picture was a cystic-macrophagic granuloma in both the injection site (upper lip) and the migrating site (paranasal regions). We think that the foreign body has undergone an antigravity migration from the upper lip to the right paranasal region. To our knowledge, such a phenomenon has not been yet reported in literature.
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
2008
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…